AVIA 435 Quiz 2
AVIA 435 Quiz 2
- How many nicad batteries are installed in the aft equipment bay?
- How many buses are part of the AC system?
- Whenever single engine taxi is performed, turn the __________ Off to prevent fuel imbalance.
- According to the Shutdown Check, what are the correct switch positions for the 10th stage bleed air switches on the BLEED AIR PANEL?
- The 14th stage Bleed Air Leak Detection System uses a __________ overheat detection system.
- What is the source of air to the distribution manifold?
- In the wing leading edge, the wing anti-icing system uses a __________ overheat detection system.
- Bleed air from the 10th stage is used for __________.
- Each generator incorporates a GCU. Each GCU will remove itself from the bus system (Disable output) for the following reasons (Ref: CR2 OM 11-6.3)
- The 10th stage pneumatic system receives bleed air from __________.
- The FMS calculated thrust value can be displayed as.
- During the engine start sequence, at what N2 RPM does the start valve close and the starter disengage?
- Which of the following is required to be selected Off for takeoff?
- According to the Originating Check, what is the correct switch positions for the left and right 14th stage SOVs on the BLEED AIR PANEL? (Ref: CR2 OM 2-3.4)
- The maximum permissible fuel imbalance between the contents of the main left tank and the main right tank is __________ lbs.
- The APR system is armed for takeoff when:
- What is the maximum permissible individual loading on each main AC generator at 35,000 feet?
- Pushing an ENG FIRE PUSH switchlight:
- Which circuit breaker panel is located behind the First Officer’s seat?
- Where is the 10th stage isolation valve located?
- What is the function of the APU generator?
- During automatic powered crossflow, if a fuel imbalance of more than __________ exists between the fuel tanks, the fuel computer opens the crossflow valve associated with the low wing tank allowing fuel to flow to that wing tank.
- The 10th stage Bleed Air Leak Detection System uses a __________ overheat detection system.
- DC BUS 2 is protected by __________?
- The 14th stage bleed air system __________.
- Pressing the EMER DEPR(ESS) switchlight on the Cabin Press Control Panel drives the outflow valves fully open and allows the cabin altitude to climb to (a maximum of) __________ feet.
- With the engine vibration monitoring system, when the N1 vibe levels exceed __________ mils or greater, the color of the VIB gauge and the pointer change to amber.
- Where is the 14th stage isolation valve located? (Ref: CR2 OM 11-19.3)
- How many buses comprise the DC system?
- Which DC bus provides power to the engine and APU extinguishers and shut-off valves?
- The 10th stage bleed air SOVs are __________.
- Which of the following engine components is/are driven by the engine-mounted accessory gearbox?
- Which of the following is/are not correct concerning the two Pressure Regulating Shut-Off Valves (PRSOVs)?
- What is the power source for the internal cabin reading lights? (Ref: CR2 OM 11-6.8)
- Two __________ are installed in each wing leading edge to detect uncontrolled leakage of the anti-ice piccolo tubes.
- Which of the following is/are true concerning the automatic thrust lever retard system?
- Which of the following shut off fuel flow to the engine by closing the firewall shutoff valve?
- When no bleed air is provided or electrical power is lost, the 10th stage SOVs are
- When the (either) wing tank quantity drops below __________, the fuel computer initiates fuel transfer from the center tank to the wing tank.
- Inflight, which of the following statements is/are correct?